PRODUCT DESCRIPTION
This electronic analytical balance is a precision laboratory weighing instrument designed for accurate measurement of small sample masses. It features an enclosed glass draft shield to protect the weighing area from air currents and environmental disturbances that may affect measurement stability.
The instrument incorporates a large backlit digital display, stainless-steel weighing chamber, adjustable operating functions and a multi-button control panel for routine laboratory weighing applications.
KEY FEATURES
• High-precision electronic weighing system
• Enclosed glass draft shield
• Large illuminated digital display
• Stainless-steel weighing chamber
• Tare function
• Calibration function
• Unit selection
• Counting function
• Printing/data output function
• Adjustable integration or stability settings
• Easy-access glass doors
• Stable benchtop construction
• User-friendly control interface
CONTROL FUNCTIONS
The visible control panel includes:
• ON – Powers the instrument on
• OFF – Powers the instrument off
• CAL – Calibration function
• TARE – Resets the displayed weight to zero for container or vessel compensation
• UNIT – Selection of available weighing units
• COU – Counting function
• PRT – Print or data output function
• INT – Instrument integration or related operating setting
• ASD – Instrument-specific operating function
Note: The exact operation of individual function keys should be confirmed from the manufacturer’s operating manual.
TYPICAL LABORATORY APPLICATIONS
• Accurate sample weighing
• Preparation of analytical standards
• Preparation of reagents and solutions
• Pharmaceutical formulation
• Chemical analysis
• Quality-control testing
• Research and development
• Gravimetric analysis
• Sample preparation for instrumental analysis
• Academic and teaching laboratories
SUITABLE LABORATORY SECTORS
• Pharmaceutical laboratories
• Chemistry laboratories
• Biomedical research laboratories
• Food and beverage laboratories
• Environmental laboratories
• Quality-control laboratories
• Research institutions
• Universities and teaching laboratories
• Industrial laboratories
DRAFT SHIELD SYSTEM
The transparent glass enclosure helps reduce the influence of:
• Air currents
• Laboratory ventilation
• Sudden environmental disturbances
• Operator movement around the weighing chamber
This improves measurement stability, particularly when weighing small sample quantities.
WEIGHING CHAMBER
The enclosed weighing chamber incorporates a durable metallic working surface designed for convenient cleaning and routine laboratory operation. The glass panels provide clear visibility of the sample during weighing.
DISPLAY
The instrument features a large illuminated digital display for clear observation of weighing results. The exact display resolution and readability should be confirmed from the instrument specification label or manufacturer’s technical documentation.
CALIBRATION
The balance includes a calibration function for maintaining weighing accuracy. Calibration should be performed using an appropriate certified calibration weight corresponding to the instrument’s specified capacity and accuracy class.
For quality-controlled laboratories, calibration and verification should follow the laboratory’s standard operating procedures and applicable quality-management requirements.
GOOD WEIGHING PRACTICE
For optimum performance:
• Install the balance on a stable and vibration-free laboratory bench.
• Level the instrument correctly before use.
• Avoid locations with strong air currents or direct ventilation.
• Allow the instrument to stabilize after switching on.
• Keep the draft shield closed during precision weighing.
• Use clean and appropriate weighing vessels.
• Avoid touching samples or weighing vessels directly with bare hands when high precision is required.
• Allow samples to reach suitable laboratory temperature before weighing.
• Perform routine calibration and performance verification.
SAFETY AND OPERATING PRECAUTIONS
• Operate the instrument on a stable, level and dry surface.
• Protect the balance from excessive vibration and impact.
• Do not exceed the specified maximum weighing capacity.
• Keep liquids and corrosive chemicals away from electronic components.
• Clean chemical spills promptly using an appropriate procedure.
• Use the correct power supply specified by the manufacturer.
• Disconnect the instrument before maintenance or extensive cleaning.
• Handle the glass draft shield carefully.
CLEANING AND MAINTENANCE
• Switch off and disconnect the balance before cleaning.
• Remove loose sample residues carefully.
• Clean the weighing chamber with a soft, suitable laboratory cloth.
• Avoid abrasive cleaning materials.
• Do not allow liquids to enter the electronic housing.
• Keep the glass panels clean for clear visibility.
• Periodically verify balance performance using suitable certified reference weights.
• Arrange professional servicing when required.
WLS PRODUCT CLASSIFICATION
Laboratory Equipment → Weighing Equipment → Electronic Analytical Balance
WLS QUALITY INSIGHT
A precision electronic balance with a glass draft shield is an essential instrument for laboratories requiring reliable measurement of small sample masses. The enclosed weighing chamber helps minimize environmental interference, while the digital control functions support routine analytical, research and quality-control weighing operations.
IMPORTANT TECHNICAL NOTE
The exact manufacturer, model number, maximum weighing capacity, readability, repeatability, linearity, calibration method, weighing units, power requirements and communication interface are not clearly identifiable from the available image.
These specifications should therefore be verified from the equipment nameplate, packaging, operating manual or official manufacturer’s technical documentation before publication or procurement.
WLS does not recommend assigning unverified numerical specifications to laboratory equipment.
SUPPLIED BY
WINLABS & STORES (WLS)
Research | Technology | Innovations









Reviews
There are no reviews yet.